Mi sitio web
|
|
|
|
Si buscas
hosting web,
dominios web,
correos empresariales o
crear páginas web gratis,
ingresa a
PaginaMX
Fuel Lift Pump Override Test on Cummins INSITE Software (CUMMINS Engines)26 Jan 21 - 01:20 Electric Fuel Lift Pump Override Test Figure 1.1 – Fuel Lift Pump (Cummins QSK50/60) #About To manually override the Electric Fuel Lift Pump: Figure 1.2 – ECM Diagnostic Tests 3). Click Next, and the Fuel Lift Pump Override window opens. Figure 1.3 – Electric Fuel Lift Pump Override Test 4). Observe and perform anything specified in the Instructions box. 5). Click Start. Figure 1.4 – Starting Electric Lift Pump Override Test 6). Select Commanded Lift Pump Position to On, the Electric Fuel Pump should activated and primes the fuel system. Figure 1.5 – Electric Lift Pump Commanded On Figure 1.6 – Electric Lift Pump Commanded Off 7). Click Stop when the test is complete. Figure 1.7 – Test has Stopped 8). To return the lift pump to its automatic settings: click Back to perform a different test. |
|
Tu Sitio Web Gratis © 2025 Mi sitio web39318 |